TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
b.
Indicator Lights (cont).
(3) LOW FUEL INDICATOR Light and Circuit Board (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY
6
Circuit
Two electrical
Connect
To circuit board terminals as
board (12)
leads (10 and
tagged. Solder leads to
18)
terminals
INSTALLATION
7
Instrument
a. Washer (17)
Position
On housing (16)
panel, top
b. Housing (16)
Install
In instrument panel opening
8
Instrument
a. Lock washer
Install
Tighten nut (14)
panel,
(15) and nut
underside
(14)
b. Circuit board
a. Position
At instrument panel
(12) with
b. Secure
Tape circuit board to instru-
leads
ment panel as noted during
removal
c.
Two electrical
Position
On fuel gage mounting stud
leads (9 and
10)
d.
Lock washer (8)
Install and
Secures leads (9 and 10)
and nut (7)
tighten
e.
Two electrical
Position
On fuel gage IGN terminal
leads (3 and
4)
f.
Two electrical
Position
On fuel gage SENDER terminal
leads (5 and
6)
g.
Two lock wash-
Install and
Secures leads (3 thru 6)
ers (2) and
tighten
nuts (1)
h.
Bulb (13) and
Install
socket (11)
9
Cab
Instrument panel
Lower and
secure
10
Battery
Battery ground
Connect
box
cable
2-254
|