TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
b.
Indicator Lights (cont).
(3) LOW FUEL INDICATOR Light and Circuit Board (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
1
f.
Two electrical
Disconnect
From fuel gage mounting stud
(cont)
leads (9 and
10)
g. Electrical tape
Remove
Remove tape securing circuit
board (12) to instrument
panel; note location for
installation
h. Circuit board
Remove
As an assembly
(12) with
socket (11)
and leads
i. Nut (14) and
Remove
lock washer
(15)
2
Instrument
Housing (16) and
Remove and
Lift from instrument panel
panel, top
washer (17)
separate
DISASSEMBLY
NOTE
Perform step 3 below only if necessary to replace socket (11) or circuit
board (12).
3
Circuit
Two electrical
a. Tag
board (12)
leads (10 and
b. Remove
Unsolder leads from circuit
18)
board terminals
CLEANING
4
a. Socket (11),
Clean
Wipe with clean, dry cloth
circuit board
(12), housing
(16), and
electrical
leads (3 thru
6, 9, 10, and
18)
2-252
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |