TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
a. Switches (cont).
(8) Blower Switch (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag and identify all electrical leads before disconnection and removal.
1
Instrument
a. Three electri-
Tag
panel,
cal leads (3,
underside
4, and 5)
b. Three screws
Remove
(1) and
washers (2)
c. Three electri-
Disconnect
cal leads (3,
4, and 5)
2
Instrument
a. Setscrew (6)
Loosen
panel,
b. Knob (7)
Remove
Rotate counterclockwise
top
c. Nut (8)
Remove
Support switch (9)
d. Switch (9) and
Remove
nut (10)
e. Nut (10)
Separate
From switch (9)
CLEANING
3
All parts
Clean
Wipe with clean, dry cloth
INSPECTION
4
a. Three electri-
Inspect
Replace if insulation frayed
cal leads (3,
or connectors damaged
4, and 5)
b. Knob (7) and
Inspect
Replace if cracked, broken,
switch (9)
or otherwise damaged
c. All other parts
Inspect
Replace if cracked, broken,
distorted, or threads
damaged