TM 9-2320-285-24-1
2-25.
STARTING SYSTEM MAINTENANCE (CONT)
a.
Solenoid and 70 AMP Circuit Breaker (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
1
t.
Two capscrews
Remove
Support plate (33)
(cont)(32)
u. Plate (33)
Remove
v. Screw (34) and
Remove
lock washer
(35)
w. Red wire (36)
Disconnect
x. Two locknuts
Remove
(37), washers
(38), and
screws (39)
y. Circuit breaker
Remove
(40)
z. Capscrew (41),
Remove
lock washer
(42), and
bracket (27)
CLEANING
2
a. Wires
Clean
Use clean cloth moistened
with detergent; wipe dry
using clean cloths
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water and seek medical aid immediately.
b. Solenoid (31)
Clean
Use clean cloth moistened
and circuit
with cleaning solvent P-D-
breaker (40)
680; dry using clean cloths
c. Remaining parts
Clean
Use cleaning solvent P-D-680;
dry using clean cloths
2-205
|