2-19.
INSTRUMENT PANEL TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. WATER TEMP WARNING LIGHT OR BELL NOT OPERATING PROPERLY (Cont)
Step 4.
Check continuity of diodes (para 2-35f) and brown/red electrical lead connecting diodes and bell.
a. If correct continuity is not obtained, replace diodes (para 2-35f) or repair wiring (para 2-35c(2)).
b. If correct continuity is obtained, go to step 5 below.
Step 5.
Check continuity of wiring connecting diodes and water temperature sensor.
a. If continuity is not obtained, repair or replace wiring (para 2-32c).
b. If continuity is obtained, troubleshoot water temperature sensor (para 2-21).
3. OIL PRESSURE WARNING LIGHT OR BELL NOT OPERATING PROPERLY
Step 1.
Disconnect water level sensor (para 2-29).
With engine stopped, turn key switch to on position.
OIL PRESSURE warning lamp should light and bell should sound.
a. If lamp does not light, go to step 2 below.
b. If bell does not sound, go to step 3 below.
c. If lamp lights, bell sounds, and WATER LEVEL or WATER TEMP warning lamps light, go to step
4 below.
Step 2.
Check for continuity of OIL PRESSURE warning light bulb.
a. If bulb is defective, replace (para 2-26b(4)).
b. If bulb is not defective, repair socket and wiring as required (para 2-26b(4)).
Step 3.
Disconnect warning bell electrical leads (para 2-26c(l)).
Connect 12 Vdc power source to bell.
Bell should sound.
a. If bell does not sound, replace (para 2-26c(1)).
b. If bell sounds, go to step 4 below.
2-174
|