TM 9-2320-285-24-1
2-15.
COOLING SYSTEM MAINTENANCE (CONT)
f.
Coolant Recovery System (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Radiator
a. Clamp (1)
Slide over
hose (2)
b. Hose (2)
Disconnect
From radiator and recovery
and remove
tank
c. Capscrew (3)
Remove
Support recovery tank
and nut (4)
d. Recovery tank
Remove
(5)
e. Two nuts (6)
Remove
Support bracket (8)
and lock
washers (7)
f. Bracket (8)
Remove
CLEANING
2
a. Hose (2) and
Clean
Use detergent and clean
recovery
cloth; dry using clean
tank (5)
cloth. Clean interior of
tank by allowing detergent
to stand in tank overnight
then rinse with clear
water
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear
protective goggles and gloves and use only in a well ventilated area. Avoid contact with
skin, eyes, and clothes and don't breathe vapors. Do not use near open flame or
excessive heat and don't smoke when using it. Failure to do so could cause serious
injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water and seek medical aid
immediately.
b. Remaining parts Clean
Use cleaning solvent P-D-
680; dry using clean
cloths
2-164
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |