TM 9-2320-285-24-1
2-15.
COOLING SYSTEM MAINTENANCE (CONT)
c.
Hoses (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
6
(cont)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with
compressed air. Failure to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your eyes, seek medical attention
immediately.
b. All other parts
Clean
Use cleaning solvent P-D-680;
dry with compressed air
INSPECTION
7
a. Hoses, elbows,
Inspect
Replace if cracked, split, or
and connec-
holes are apparent. Check
tors
inside diameter for block-
age; clear blockage or
replace parts
b. All other parts
Inspect
Replace if damaged or cracked
or if threads are damaged
INSTALLATION
8
Radiator,
a. Clamps (7 and
Position
On hose (10)
bottom and9)
oil cooler
b. Hose (10)
Connect
To radiator
c. Clamp (9)
Tighten
e. Elbow (8)
Install
2-146
|