2-13.
FUEL SYSTEM MAINTENANCE (CONT)
a.
Air Cleaner Assembly and Restriction Indicator.
STEP
LOCATION
ITEM
ACTION
REMARKS
SERVICING
1
Air cleaner
a. Four capscrews
Remove
element (4)
(1) and nuts
(2)
b. Two clamp
Remove
straps (3)
c. Air cleaner
Remove and
element (4)
discard
2
Precleaner
a. Two capscrews
Remove
Support precleaner (8) and
(8)
(5) and nuts
bracket (7)
(6)
b. Bracket (7) and
Remove and
precleaner
separate
(8)
c. Vacuator valve
Remove
Pull from precleaner (8)
(9)
WARNING
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with
compressed air. Failure to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your eyes, seek medical attention
immediately.
d. Precleaner (8)
Clean
Turn vacuator valve inside
vacuator
out and clean with mild
valve (9),
solution of detergent and
and element
water; dry using compressed
(4)
air
3
Air cleaner
a. Air cleaner
Position
Install new element every
element
element (4)
third service interval
(4)
b. Two clamp
Position
Over air cleaner element (4)
straps (3)
c. Four capscrews
Install and
(1) and nuts
tighten
(2)
4
Precleaner
a. Vacuator valve
Install
Push onto precleaner (8);
(8)
(9)
position rubber seal paral-
lel to front of precleaner
b. Bracket (7)
Position
Over precleaner (8)
2-68