HEATER SHUTOFF VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
15. Oil cooler
Nipple (5)
a. Wrap threads with teflon tape
assembly (4)
(page 4-1).
b. Screw in but do not tighten.
16. Nipple (5)
Elbow (3)
Screw on and tighten using pipe wrench.
17. Elbow (3)
Reducer (1)
a.
Wrap threads with teflon tape
(page 4-1).
b.
Screw in and tighten using 1 1/16-
inch wrench.
18. Reducer (1)
Valve (2)
a.
Wrap threads with teflon tape
(page 4-1).
b.
Screw in and tighten using 11/16-
inch wrench.
19. Valve (2)
Hose (6)
Lube lightly with soap and push on
until seated.
TA240821
4-1305