TM 9-2320-270-20-3
HEATER HOSES - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
INSTALLATION - CONTINUED
Slide on.
Clamps (3) and (4)
Return hose (1) and
40.
heater hose (2)
Lube elbow (5) lightly with soap and
Return heater
Elbow (5)
41.
push on until seated.
hose (1)
Slide into place and tighten using
Clamp (3)
Return hose (1)
42.
screwdriver.
to elbow (5)
Lube end of valve (6) lightly with soap
Heater hose (2)
Control valve (6)
43.
and push on until seated.
Slide into place and tighten using
Clamp (4)
Heater hose (2)
44.
screwdriver.
to control valve (6)
put around.
Loop clamp (9)
Return hose (1),
45.
heater hose (2) and
other hoses and
cables (7) to oil
cooler (8)
Screw in, and tighten using 1/2-inch
New Iockwasher (10)
Loop clamp (9) to
46.
socket and handle.
and screw (11)
oil cooler(8)
Using pliers, put on.
New tie wraps (12)
Return hose (1),
47.
heater hose (2) to
other hoses and
cables (7)
Fill (TM 9-2320-270-10).
Cooling system
48.
4-1300
|