TM 9-2320-270-20-3
HEATER KNOB AND CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
18. Cable (2) to
Setscrew (12)
a. Using long-nose pliers, bend end over.
swivel (8)
b. Using 1/8-inch screwdriver, tighten.
19. Cable (2) to shut-
Clamp screw (13)
With clamp (10) over conduit (14), and
off valve (7)
using 1/4-inch socket and handle, tighten.
20. Cable (2) to heater
New tie wraps (17)
Using slip-joint pliers, put on.
hoses (15) and
wires (16)
NOTE
FOLLOW-ON MAINTENANCE:
1. Check operation (TM 9-2320-270-10).
2. Close right side of hood and install right hood side panel (TM 9-2320-270-10).
TASK ENDS HERE
TA240808
4-1287
|