TM 9-2320-270-20-3
DEFROSTER KNOB AND CABLE - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
INSTALLATION CONTINUED
a. Make sure defroster knob(3) is pushed
Cable (2)
15. Cable support (1)
in.
b. Make sure defroster door arm (4) is all
the way to the left.
c. Put cable (2) in place.
a. Hook tab in hole.
Cable clip (5)
16. Cable (2) to
b. Snap on.
support (1)
Screw in and tighten using cross-tip
Screw (6)
17. Cable clip (5) to
screwdriver.
support (1)
Nut (8)
18. Cable (2) to heater
control panel (7)
NOTE
FOLLOW-ON MAINTENANCE: Check operation (TM 9-2320-270-10).
TASK ENDS HERE
TA240798
4-1274
|