TM 9-230-270-20-3
WIPER CONTROL VALVE - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
INSTALLATION
Put on.
New Iockwasher (2)
18. Valve (1)
Put in place.
Valve (1)
19. Instrument panel (3)
Screw on and tighten using 3/4-inch
Nut (4)
20. Valve (1) to
wrench.
instrument panel (3)
NOTE
Step 21 also applies to air line 32 on left valve.
a.
Lube end lightly with soap and push in
Air line 35 (6)
21. Adapter (5)
until seated.
b.
Screw on and tighten using 9/16-inch
wrench.
NOTE
Step 22 also applies to air line 37 on right valve.
Lube end lightly with soap and push in
a.
Air line 34 (8)
22. Adapter (7)
until seated.
b.
Screw on and tighten using 9/16-inch
wrench.
NOTE
Step 23 also applies to air line 36 on right valve.
a.
Lube end lightly with soap and push in
Air line 33 (10)
23. Adapter (9)
until seated.
b.
Screw on and tighten using 9/16-inch
wrench.
Close (page 4-244).
Instrument panel
24. Cab
Place in position and line up holes.
Knob (12)
25. Shaft (11)
Screw in and tighten using 5/64-inch key.
Setscrew (13)
26. Knob (12) to
shaft (11)
4-1204
|