WINCH VALVES TO MOTORS HYDRAULIC LINES - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REMOVAL - CONTINUED
Using 2-inch wrench, unscrew and take
a.
Hose (2)
7. Tee (1)
off.
Plug hose (12).
b.
Using 5/8-inch wrench, unscrew and
a.
Four screws (4),
& Two hose clamps (3)
take off.
Iockwashers (5),
Get rid of Iockwashers (5) and
b.
hose (6) and
packing (7).
packing (7)
Plug hose (6).
c.
INSTALLATION
CAUTION
Do not overtighten hoses. Hoses or fittings will leak.
a. Take out plug.
Hose (2)
9. Tee (1)
b.  Using 2-inch wrench, screw on and
tighten.
Put in.
New packing (7)
10. Hydraulic motor (8)
a. Take out plug.
Hose (6) and two
11.
b. Put in place.
hose clamps (3)
Using 5/8-inch wrench, screw in and
Four screws (4)
12. Two hose clamps (3)
tighten.
and new
Iockwashers (5)
TA240716