TM 9-2320-270-20-2
AIR COMPRESSOR - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or excessive heat. The flashpoint
is 100F to 138F (38 to 59C). If you become dizzy while using cleaning solvent, get
fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes
with water and get medical aid immediately.
a. Plug all water, air, and oil holes.
Compressor (1)
20.
b. Using clean rags dampened with dry-
cleaning solvent, wipe clean.
c. Wipe dry with clean, dry rags.
d. Remove plugs.
CLEANING
Clean according to general maintenance
All other parts
21.
instructions (page 4-1).
lNSPECTION/REPLACEMENT
Inspect according to general maintenance
All parts
22.
instructions (page 4-1).
ASSEMBLY
Elbow (2)
a. Wrap threads with teflon tape
(page 4-1).
b. Screw in and tighten using 1 1/8-inch
wrench.
a. Wrap threads
with teflon tape
Two elbows (3)
24.
(page 4-1).
b. Screw in and
tighten using 5/8-inch
wrench.
.
Elbow (4)
a. Wrap threads
with teflon tape
25.
(page 4-1).
b. Screw in and
tighten using 7/16-inch
wrench.
Install (page 4-855).
Air compressor air
26.
strainer assembly
4-846
|