TM 9-2320-270-20-2
ACCESSORY AIR MANIFOLD - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
NOTE
Tag air lines according to general maintenance instructions (page 4-1).
Drain (TM 9-2320-270-10).
Air system
1.
Using 5/8-inch wrench, unscrew and pull
Air line 533 (2)
2. Elbow (1)
out.
Using long-nose pliers, pull out.
insert (3)
3. Air line 533 (2)
or elbow (1)
Using 5/8-inch wrench, unscrew and pull
Air line (5)
4. Elbow (4)
out.
Using long-nose pliers, pull out.
Insert (6)
5. Air line 71 (5)
or elbow (4)
Air line 35 (8)
Using 9/16-inch wrench, unscrew and pull
6. Adapter(7)
out.
Using long-nose pliers, pull out.
Insert (9)
7. Air line 35 (8)
or adapter(7)
Using 9/16-inch wrench, unscrew and pull
Air line 032 (11)
8. Adapter (10)
out.
Insert (12)
Using long-nose pliers, pull out.
9. Air line 032 (11)
or adapter (10)
Using 5/8-inch wrench, unscrew and pull
Air line 492 (14)
10. Tee (13)
out.
Using long-nose pliers, pull out.
Insert (15)
11. Air line 492 (14)
or tee(13)
Using 5/8-inch wrench, unscrew and pull
Air line 694 (16)
12. Tee (13)
out.
4-744
.
|