TM9-2320-270-20-2
SECONDARY AIR RESERVOIR CHECK VALVE- CONTINUED
ACTION
REMARKS
ITEM
LOCATION
a. Wrap threads with teflon tape
Elbow (1)
9. Check valve (4)
(page 4-1).
b. Screw in and tighten using 1 1/16-inch
wrench.
Push in and using plastic hammer, seat.
Insert (3)
10. Elbow (1)
a. Lube end lightly with soap and push in
Air line 654 (2)
11.
until seated.
b. Screw on and tighten using 1 1/8-inch
wrench.
NOTE
FOLLOW-ON MAINTENANCE: Check for leaks (page 4-1).
TASK ENDS HERE