TM9-2320-270-20-2
CABLE DRAIN VALVE AND CABLE - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
Drain valve (11)
a. Wrap threads with teflon tape
16. Elbow (9) to wet
(page 4-1).
reservoir (10)
b. Screw in and tighten using 1 1/16-
inch wrench.
Push through.
Cable (6)
17. Loop clamp (12)
Push through hole in valve lever (13)
Cable (6)
18. Drain valve (11)
and, using tape measure, position so end
of conduit (14) is 1 1/2 to 2 inches
(3.8 to 4 centimeters) from lever (13).
a. Put on.
19. Drain cable (6)
stop (15)
b. Using tape measure, position stop (15)
so it is 1/4 to 1/2 inches (.63 to 1.3
centimeters) from lever (13).
Screw in and tighten using screwdriver
Screw (16)
20. stop (15) to
and pliers.
cable (6)
NOTE
FOLLOW-ON MAINTENANCE: Check for leaks (page 4-1).
TASK ENDS HERE
TA240461
4-713
|