WET RESERVOIR - CONTINUED
ACTION
REMARKS
LOCATION
ITEM
REMOVAL
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Air
Parts under pressure can, when removed, fly off with great force causing injury to
personnel.
NOTE
Tag air lines according to general maintenance instructions (page 4-1).
Air system
Drain (TM9-2320-270-10).
1.
Using screwdriver and slip-joint pliers,
2. stop (1)
Screw (2)
unscrew and take out.
Take off.
stop (1)
3. Drain cable (3)
4. Drain valve
Pull out.
Drain cable (3)
assembly (4) and
loop clamp (5)
Drain valve
Using 1 1/16-inch wrench, unscrew and
5. Wet reservoir (6)
take out.
assembly (4)
TA240432
4-659