TM9-2320-270-20-2
NYLON TUBING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REPAIR OF IN-LINE SECTION
WARNING
Make sure all pressure is drained from air system before disconnecting air line. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
NOTE
Long breaks, or a series of breaks in the tubing can be repaired by installing a repair
section.
70.
Air system
Drain (TM 9-2320-270-10).
71. Nylon tube (8) to
Tie wrap (10)
a. Using cutting pliers, cut and take off.
other nylon tubes (9)
b. Get rid of.
72.
Nylon tube (8)
Using pocket knife, cut out damaged
section.
73.
Repair section (11)
Using pocket knife, cut from bulk to
same length as the damaged area.
TA240425
4-647
|