TM9-2320-270-20-2
NYLON TUBING - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REPAIR OF TUBE-END SECTION CONTINUED
Using 5/8-inch wrench, unscrew and slide
Nut (3)
51. Nylon tube (1) to
back.
adapter (2)
Pull out.
Nylon tube (1)
52. Adapter (2)
NOTE
Insert may stay in adapter or in nylon tube.
a. Using long-nose pliers, pull out.
Insert (4)
53. Fitting (2) or
b. Inspect to see if it is cracked,
nylon tube (1)
dented, or crushed.
Replace damaged insert.
Using pocket knife, cut off beyond
Nylon tube (1)
54.
damage.
a. Slide off.
Nut (3)
55. Nylon tube (1)
b. Inspect for cracks or stripped threads.
Replace damaged nut.
TA240422