TM 9-2320-270-20-1
HIGH WATER TEMPERATURE SWITCH -CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING/lNSPECTION
3.
High water tempera-
a.
Using wire brush, clean off old sealing
ture switch (1)
tape.
b.
Inspect switch for stripped or damaged
threads and cracks.
Replace damaged switch.
INSTALLATION
4. Thermostat
High water temper-
Wrap threads with teflon tape
a.
housing (7)
ature switch (1)
b.
Screw in and tighten using 7/6-inch
wrench.
Wire 320 (4), new
5. High water tempera-
Screw on and tighten using 3/8-inch
Iockwasher (3),
ture switch (1)
wrench.
washer (5),
insulator (6), and
nut (2)
NOTE
FOLLOW-ON MAINTENANCE:
1.
Fill cooling system (TM 9-2320-270-10).
2.
Install left hood side panel and close left side of hood (TM 9-2320-270-10).
TASK ENDS HERE
TA240074