TM 9-2320-270-20-1
NEUTRAL SAFELY RELAY - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REMOVAL CONTINUED
Screw (2)
Using flat-tip screwdriver, unscrew part
1. Terminal (1)
way.
Pull out.
2.
Wire 376 (3)
Using flat-tip screwdriver, unscrew part
Screw (5)
3. Terminal (4)
way.
4.
Pull out.
Wire 330 (6)
5. Terminal (7)
Using flat-tip screwdriver, unscrew part
Screw (8)
way.
Pull out.
Wire 279 (9)
6.
7. Terminal (10)
Using flat-tip screwdriver, unscrew part
Screw (11)
way.
Pull out.
Wire 330 (12)
8.
Two screws (16),
9. Neutral safety relay
a. Using cross-tip screwdriver, unscrew
Iockwashers (17),
(13) and horn
and take off.
wire 330 (6), and
relay (14) to
b. Get rid of Iockwashers (17).
firewall (15)
330 (12)
Neutral safety
10. Firewall (15)
Take off.
relay (13)
INSTALLATION
11. Firewall (15)
Place in position.
Neutral safety relay
(13) and horn
relay (14)
Two screws (16), two
12. Neutral safety relay
Put together and, using cross-tip screw-
(13) and horn
new Iockwashers
driver, tighten.
(17), wire 330 (6),
relay (14) to
firewall (15)
and wire 330 (12)
13. Terminal (10)
Wire 330 (12)
Put in.
4-240
|