TM9-2320-270-20-1
THERMOSTAT HOUSINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
28. Left thermostat
Plug (8)
a. Put container underneath.
housing cover (7)
b. Using key, unscrew and take out.
c. When coolant stops draining, screw in
until flush with cover (7) using key.
d. Get rid of fluid (page 4-1).
29. Two wires (9 and 10)
Two nuts (13) and
a. Using 1 1/32-inch and 3/8-inch
to two senders
Iockwashers (14)
wrenches, unscrew and take out.
(11) and (12)
b. Get rid of Iockwashers (14).
30. Two senders (11)
Two wires (9)
a. Take off.
and (12)
and (10)
b. Tag (page 4-1).
31. Five hose
Five screws (16)
Using screwdriver, unscrew part way.
clamps (15)
32. Two elbows (17)
Two hoses (18)
Using 9/16-inch wrench, unscrew and take
off.
33. Left thermostat
Hose (20) and
Using 1 3/6-inch wrench, unscrew.
housing (19)
adapter (21)
TA239931
4-189
|