TM9-2320-270-20-1
THERMOSTAT HOUSINGS - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
RIGHT SIDE THERMOSTAT HOUSING REMOVAL CONTINUED
a.
Put container underneath.
Plug (2)
3. Engine (1)
Using handle with 1/2-inch drive, un-
b.
screw and take out.
When coolant stops draining, screw in
c.
until flush using handle with 1/2-inch
drive.
Put container underneath.
a.
Plug (4)
4. Thermostat housing
Using key, unscrew and take out.
b.
cover (3)
c.
When coolant stops draining, screw in
until flush with cover (3) using key.
d. Get rid of fluid (page 4-1).
Using screwdriver, unscrew part way.
Screw (6)
5. Clamp (5)
a. Put container underneath.
Hose (8)
6. Fitting (7)
b. pull off.
c. Get rid of fluid (page 4-1).
TA239926