TM9-2320-270-20-1
AIR CLEANER FILTERS - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REMOVAL CONTINUED
Using 1/2-inch socket, handle, exten-
TWO bolts (3)
3. Strap (1) to
sion, and 1/2-inch wrench, unscrew and
and nuts (4)
two brackets (2)
take out.
Take off.
Strap (1)
4. Filter (5)
Using 1/2-inch socket, handle, and 1/2-
TWO bolts (8)
5. Strap (6) to two
inch wrench, unscrew and take out.
and nuts (9)
brackets (7)
Take off.
Strap (6)
6. Filter (5)
Using 9/16-inch socket, handle, and 9/16-
Four bolts (12) and
7. Front bracket (10)
inch wrench, unscrew and take out.
nuts (13)
to housing (11)
Take off.
Front bracket (10)
8. Housing (11)
WARNING
After Nuclear, Biological, or Chemical (NBC) exposure of this vehicle, all air filters
shall be handled with extreme caution. Unprotected personnel may experience injury or
death if residual toxic agents or radioactive material are present. If vehicle is exposed to
chemical or biological agents, servicing personnel shall wear protective mask, hood,
protective overgarments, and chemical protective gloves and boots. All contaminated
air filters shall be placed into double-lined plastic bags and swiftly moved to a
segregation area away from the worksite. The same procedure applies for radioactive
dust contamination, however, the Company NBC team should measure the radiation
prior to filter removal to determine the extent of safety procedures required per the NBC
Annex to the unit Standard Operating Procedures (SOP). The segregation area in which
the contaminated air filters are temporarily stored shall be marked with appropriate NBC
placards. Final disposal of contaminated air filters shall be in accordance with local
SOP.
Take off.
9. Fender (14)
Filter (5)
Using 1/2-inch socket and handle, loosen,
Four screws (16)
10. Four tabs (15) to
but do not remove.
housing (11)
Move four tabs (15) and take out.
Filter (5)
11. Housing (11)
4-46
|