TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PERSONNEL HEATER AND DEFROSTER SYSTEM
76. HEATER MOTOR DOES NOT WORK.
Turn on heater (TM 9-2320-270-10). Check if heater works only on high or low
Step 1.
speed, or not at all.
If motor works on low speed only, turn heater off (TM 9-2320-270-10)
and go to step 4.
Open instrument panel (page 4-244). If heater works on high speed only, go to
Step 2.
terminal for wire no. 071 (1) on resistor. Set switch (2) on low speed. Using
multimeter set at 30 vdc, put red probe on wire no. 071 terminal and black probe
to good ground.
a. If meter reads voltage, turn heater off (TM 9-2320-270-10) and
replace resistor (page 4-1315).
b. If meter does not read voltage, turn heater off (TM 9-2320-270-10),
close instrument panel (page 4-244), and notify direct support
maintenance.
Close instrument panel (page 4-244). Disconnect motor ground wire (3) from
Step 3.
ground point. Put switch (2) in on position. Using multimeter set at 30 vdc, put
red probe on ground wire and black probe to good ground.
If meter reads voltage, put switch in OFF position and reattach ground
wire to good ground.
Step 4.
With motor ground wire reattached and switch (2) in ON position, go to radio
interference suppressor (4). Using multimeter set at 30 vdc, put red probe on
terminal (5) for wire leading to heater motor and black probe to good ground.
If meter reads voltage, replace heater motor (page 4-1270).
Put heater switch (2) in OFF position. Remove radio interference suppressor (4)
Step 5.
from line. Using multimeter set at RX-1, check capacitor for continuity.
If meter does not read continuity, replace suppressor (page 4-1316).
3-202
|