TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
65. UNEVEN OR ERRATIC SERVICE BRAKES ON PUSHER AXLE.
Check both brakedrums (1) and brakeshoes (2) for damage or foreign material
Step 1.
(page 4-910).
If brakedrums or shoes are damaged or dirty, replace clean (page
4-910) or (page 4-616), or notify direct support maintenance for
repair.
Check four air chambers and wedge assemblies (3) for damage and freedom of
Step 2.
movement (page 4-1).
If air chambers or wedge assemblies are damaged or binding, replace
(page 4-692) and (page 4-615), or notify direct support maintenance
for repair.
Check hoses from brake chambers (3) to pusher axle relay valve (4) for damage
Step 3.
or leaks by listening for hissing or using soap solution and watching for
bubbles (page 4-1).
If hoses are damaged or leaking, repair or replace (page 4-609).
Check pusher axle relay valve (4) for damage or leaks by listening for hissing or
Step 4.
using soap solution and watching for bubbles (page 4-1).
If valve is damaged or leaking, replace (page 4-779).