|
|
TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
62. SERVICE BRAKES FAIL TO APPLY OR RELEASE, OR APPLY OR RELEASE SLOWLY CONTINUED.
Step 13.
Check four hoses (1) from rear axle relay valve (2) to four rear axle
brake chambers (3) for damage or leaks by listening for hissing or
using soap solution and watching for bubbles (page 4-1).
If hoses are damaged or leaking, repair or replace (page 4-609).
Check four rear axle brake chambers (3) for damage, clogs, or sticking
Step 14.
parts (page 4-1).
If brake chambers are damaged, clogged, or sticking, clean or
replace (page 4-701).
3-144
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |