MALFUNCTION
TEST OR INSPECTION
CORRECTIVE
ACTION
61. SPRING BRAKES DO NOT APPLY CONTINUED.
Step 6.
Check spring brakes (1) for mud, stones, or other obstructions.
If brakes are obstructed, clear away obstructing material (page 4-1).
Step 7.
Cage spring (TM 9-2320-270-10) and check if spring (2) is broken.
If spring is broken, replace air chamber (page 4-701).
Disconnect plunger end (3) from slack adjuster (4). Check slack adjuster and
Step 8.
camshaft (5) for damage and freedom of movement.
If slack adjuster and camshaft are damaged, or do not move freely, re-
place (page 4-624).
Connect slack adjuster to plunger end and uncage air chamber spring
Step 9.
(TM 9-2320-270-10). Check brakedrum (6) and brakeshoes (7) for damage
and adjustment (page 2-35).
a. If brakedrum or brakeshoes are damaged, or out of adjustment, ad-
just, replace (page 4-621), or notify direct support maintenance for
repair.
b. If spring brakes still do not apply, notify direct support maintenance.
TA239727