TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
34. PARKING BRAKE VALVE STOPLIGHT SWITCH INOPERATIVE CONTINUED.
At diode (1), using multimeter set at 30 vdc, disconnect plug on wire no.
Step 4.
360. Put red probe on wire no. 360 (2), and black probe on good ground.
If meter reads no voltage, plug in wire, close instrument panel (page
4-244) and notify direct support maintenance.
At diode (1), disconnect wire no. 429 (3). Using multimeter set at 30 vdc,
Step 5.
put red probe on diode and black probe to good ground.
If meter reads no voltage, replace diode (page 4-323).
Step 6.
At disconnected end of diode wire no. 429 (3), using multimeter set at
30 vdc, put red probe on wire no. 429 and black probe to good ground. Apply
brakes.
Plug in wire no. 429 (3), close instrument panel (page 4-244), and
notify direct support maintenance.
TA239683
3-96
|