TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
27. SHIFT CONTROL LIGHT DOES NOT WORK.
NOTE
If instrument panel gage lights do not work, do steps 4 thru 8 under INSTRUMENT PANEL
GAGE LIGHT DOES NOT WORK (page 3-77).
Remove shift control lamp (page 4-519). Using multimeter set at RX1, put
Step 1.
probes on contact (1) and lamp housing (2).
If meter does not read zero, replace lamp (3) (page 4-519).
Using multimeter set at RX1, put probes in end of black ground wire (4) and
Step 2.
housing (5). Take reading and wrap wire with electrical tape.
Install shift control lamp (page 4-519), and notify direct support
maintenance.
TA239659