TM 9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BOTH HEADLIGHTS DO NOT WORK CONTINUED.
16.
Using multimeter set at 30 vdc, put red probe on circuit breaker terminal (1)
Step 8.
and black probe on panel (2).
If meter reads no voltage, put headlight switch in OFF position, close
instrument panel (page 4-244) and notify direct support
maintenance.
Open right side of hood (TM 9-2320-270-10), unscrew and disconnect firewall
Step 9.
harness plug (3). Using multimeter set at 30 vdc, put red probe on socket
terminal R (4) and black probe on bulkhead (5).
If meter reads no voltage, put headlight switch in OFF position,
close instrument panel (page 4-244), plug in firewall harness,
close right side of hood (TM 9-2320-270-10) and notify direct
support maintenance.
TA239641
3-52
|