TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. FUEL LEVEL GAGE SHOWS INCORRECT FUEL LEVEL CONTINUED.
Install right side panel and close right side of hood (TM 9-2320-270-10). Using
Step 6.
multimeter set at 30 vdc, put red probe on fuel gage terminal (1) and black probe
on panel (2).
a. If meter reads no voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
b. If meter reads voltage, put key in OFF position and replace fuel level
gage (page 4-268).
c. If fuel level gage still shows incorrect level, put key in OFF position,
close instrument panel (page 4-244) and notify direct support
maintenance.
TA239623
3-34
|