TM 9-2320-269-34-1
SUBMERGED FUEL PUMP WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
6.
Lead wire
Connector (2)
a.
Using 1/4-inch flat-tip screwdriver,
connector (1)
pry up on retainer.
b.
Pull apart.
7.
Bulk connector (3)
Lead wire (4)
Using diagonal cutting pliers, cut.
Leave enough wire at plug to splice
to new harness.
8.
Harness (5)
Two wire clips (6)
Using 1/4-inch flat-tip screwdriver, pry
off.
9.
Grommet (7)
Harness (5)
Pull out.
TA238302
2-556
|