TM 9-2320-269-34-1
ANTILOCK WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when using
solvent. Failure to observe these precautions could cause serious injury or death.
19.
Terminals (5)
Clean with clean rag dampened with dry-
cleaning solvent.
20.
Connectors (6)
Wipe clean with clean, dry rag.
21.
Wiring harness (7)
a. Wipe clean with rag dampened with
water.
b. Wipe dry using clean, dry rag.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-46).
Replace damaged or defective parts, as needed.
22.
Wiring harness (7)
a.
Look for cut, burned, and worn
insulation.
b. Look for broken wires, and replace as
necessary.
23.
Connectors (6)
Look for missing, broken, a nd corroded
parts, and replace as necessary.
2-489
|