TM 9-2320-269-34-1
STARTING MOTOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when
using solvent. Failure to observe these precautions could cause serious injury or death to
personnel and to equipment.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-46).
58.
Solenoid switch
a.
Wipe clean with clean rag dampened
assembly (1), arma-
with drycleaning solvent.
ture (2), field
b.
Wipe dry with clean, dry rag.
frame (3), and drive
clutch (4)
59.
Commutator (5)
a.
Lightly clean with number 00 sand-
paper.
b.
Take off dust with low pressure com-
pressed air.
60.
Eight brushes (6)
Clean with clean, dry rag.
61.
Field coils (7)
Wipe clean with non-sudsing detergent.
62.
All other metal
a.
Clean in drycleaning solvent.
parts
b.
Wipe dry with clean, dry rag.