TM 9-2320-269-34-1
WATER PUMP-TO-CRANKCASE MANIFOLD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-46).
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when
using solvent. Failure to observe these precautions could cause serious injury or death.
8.
All metal parts
a.
Clean in drycleaning solvent.
b.
Wipe dry with clean, dry rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-46).
Replace damaged or defective parts as necessary.
9.
Water pump-to-
Look for cracks, breaks, and large dents.
manifold (1)
10.
All threaded parts
Look for stripped or gouged threads.
ASSEMBLY
11.
Water pump-to-
Connector (2)
a.
Put manifold (1) in vise.
b.
Using 11/16-inch open-end wrench,
manifold (1)
screw in and tighten.
12.
Elbow (3)
a
Using 1-inch open-end wrench, screw
in and tighten.
b.
Take manifold (1) out of vise.
2-412
|