TM 9-2320-269-34-1
LEFT WATER OUTLET - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1. Left water
Three screws (2) and
a. Using 9/16-inch deep well socket and
outlet (1)
lockwashers (3)
ratchet handle with 3/8-inch drive,
unscrew and take out.
b. Get rid of lockwashers (3).
2. Adapter (4)
Water pipe
Using 1 1/16-inch and 1 1/8-inch
assembly (5)
open-end wrenches, unscrew and take off.
Left water outlet
a. Take off.
cover (6) and
(1) and gasket (8)
b. Get rid of gasket (8)
left cylinder
Gasket may stay on head.
head (7)
DISASSEMBLY
4. Left water
Water pipe (9) and
a. Put outlet (1) in vise.
outlet (1)
two packings (10)
b. Slide out.
c. Using slip-joint pliers, take out
packings (10).
d. Get rid of packings (10).
5.
Pipe plug (11)
Using 5/8-inch open-end wrench, unscrew
and take out.
6.
Adapter (4)
a. Using 1 1/16-inch open-end wrench,
unscrew and take out.
b. Take outlet (1) out of vise.
CLEANING
NOTE
For more Information on how to clean parts, go to General Maintenance Instructions (page 2-46).
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when
using solvent. Failure to observe these precautions could cause serious injury or death.
7.
All metal parts
a. Clean in drycleaning solvent.
b. Wipe dry with clean, dry rags.
2-392
|