TM 9-1300-277
Figure 4-15. M1A4 priming adapter.
Figure 4-17. Detonating cord connector,
WARNING
ONLY USE SILVER CHLORIDE DRY
CELL BATTERIES WHICH PRODUCE
0.9 VOLTS IN THE GALVANOMETER
(TABLE 4-2). OTHER BATTERIES
MAY
PRODUCE
SUFFICIENT
VOLTAGE TO DETONATE ELECTRIC
BLASTING CAPS.
WHEN THE
GALVANOMETER IS NOT BEING
USED FOR EXTENDED PERIODS OF
Figure 4-16. M1 detonating cord clip.
TIME, THE BATTERIES SHOULD BE
REMOVED BECAUSE OF THEIR
TENDENCY TO CORRODE.
(2) M51 blasting cap test set. This test set
galvanometer for continuity testing of electrical firing
circuits. The test set is a self-contained unit with a
magneto-type impulse generator, an indicator lamp, a
handle
Change 1
4-14
|