TM 9-1290-335-34&P
5-3.
BACKLASH ADJUSTMENT
TOOLS:
Machinist scriber
1/8" socket head screw key (Allen wrench or equivalent)
Vise
1/4" flat tip screwdriver
PERSONNEL: One
EQUIPMENT CONDITION: Azimuth indicator on work bench
FRAME 1
Step
Procedure
NOTE
When clamping azimuth indicator with -a vise, make
sure that drive gear can be reached by hand. Do not
tighten vise too much.
1.
Using vise, clamp azimuth indicator in upright position.
2.
Turn drive gear (1) until directional pointer (2) is pointing to "0".
3.
Press down on resetter knob (3) and turn to set azimuth pointer (4) to "O'".
4.
Release pressure to resetter knob (3). Turn resetter knob (3) and set micrometer
pointer (5) to "0".
GO TO FRAME 2
Vol II
Para 5-3
5-2