TM 9-1290-335-34&P
4-23.
MIDDLE HOUSING ASSEMBLY AND RELATED PARTS ASSEMBLY
(CONT)
FRAME 2
Step
Procedure
1.
Install stud (1) into housing assembly (2).
2.
Using Allen wrench, install setscrew (3) until stud (1) is held in place. Do not tighten.
3.
Using grease, lubricate drive gear (4) and shaft (drive) (5) (JPG).
4.
Install shaft (drive) (5) into housing assembly (2) and hold in place.
5.
Place drive gear (4) over shaft (drive) (5) and line up holes.
6.
Place pin (6) into drive gear (4) and shaft (5) holes.
7.
Using punch and hammer, drive pin (6) through shaft (5) to hold drive gear (4)
GO TO FRAME 3
Vol II
Para 4-23 Cont
4-30
|