TM 9-1290-335-34&P
4-19.
DIAL HOUSING ASSEMBLY AND RELATED PARTS INSTALLATION
(CONT)
FRAME 1
Step
Procedure
1.
Place gasket (1) on middle housing assembly (2) and line up holes.
2.
Place housing assembly (3) over gasket (1), line up holes, and using four screws (4), secure housing
assembly (3) to middle housing assembly (2).
3.
Place spacer (5) in housing assembly (3).
4.
Place felt (6) on housing assembly (3).
5.
Place dial (7) with 0 at mark on housing assembly (3) and line up holes.
6.
Using screwdriver, install four screws (8) to hold dial (7) to housing assembly (3).
NOTE
FOLLOW-ON MAINTENANCE
Install pointers (para 4-14).
Do checkout procedure (Vol I, para 2 -2).
END OF TASK