TM 9-1290-232-34&P
4-14.
WORM SHAFT ASSEMBLY (CONT)
Procedure
Step
Using spanner wrench, install retainer (1).
1.
Using 1/8" flat tip screwdriver, put in screw (2).
2.
Put bearing (3) and spring (4) into housing (5).
3.
Using 1/4" flat tip screwdriver, install plug (6).
4.
Install micrometer assembly (para 4-11).
5.
While turning micrometer knob (7) adjust (tighten or loosen) plug (6) until it is just
6.
tight enough-to cause a slight but smooth resistance against turning the micrometer knob
(7).
7.
P u t drop of sealing compound on threads of setscrew (8) (JPG).
Using jeweler's screwdriver, install setscrew (8) in hole (9).
8.
NOTE
FOLLOW-ON
MAINTENANCE
D o performance test (Vol I, para 2-2).