TM 9-1290-232-34&P
4-14.
WORM
SHAFT
ASSEMBLY
(CONT)
FRAME
2
Procedure
Step
Put bearing (1) and spring (2) into housing (3).
1.
2.
Using 1/4" flat tip screwdriver, install plug (4).
3.
Install micrometer assembly (para 4-11).
4.
While turning micrometer knob (5) adjust (tighten or loosen) plug (4) until it is just
tight enough to cause a slight but smooth resistance to turning the micrometer knob (5).
5.
Put sealing compound on threads of setscrew (6) (JPG).
6.
Using jeweler's screwdriver, install setscrew (6) in hole (7).
NOTE
FOLLOW-ON
MAINTENANCE
D o performance test (Vol I, para 2-2).
END
OF
TASK
II-4-24
|