TM 9-1290-232-34&P
INSPECTION UPON RECEIPT (CONT)
3-2.
JPG 41C
Clean. If cracks or dents
Check elevation fire control
1.
are found, tell your
quadrant (1) for cracks or
supervisor.
dents.
JPG 41C
Remove nicks and burrs.
Check mounting surfaces
(2)
2.
If dents are found, tell
f o r nicks, burrs or dents.
your supervisor.
3.
Using 1/8" flat tip screwdriver,
Tighten or replace if
...
check that six screws (3) are
missing.
tight.
Check that identification plate
Clean. For configurations
4.
JPG 41C
(4) can be read easily.
M13A1 and M13A1C,
put on new identification
plate (3). For
configuration M13A3,
tell
your supervisor.
Check that level vial tube (5)
5.
Tighten if loose. Replace
is not loose or cracked.
if
cracked
(M13A1C
and
M13A1
only).
Send
M13A3 or M13B1 to
depot for repair.
Using level vial wrench, check
6.
Adjust and tighten if
t h a t eccentric ring (6) is tight.
loose.
GO
TO
FRAME
2
II-3-2
|