TM 9-1220-231-34&P
4-7.
TRUNNION LINK DISASSEMBLY (CONT)
FRAME 1
Procedure
Step
1.
Clamp tube (1) in vise.
Using wire cutter, cut and remove seal (2).
2.
Using wrench, loosen screw (3).
3.
Turn drive connector (4) clockwise until it comes off of tube (1).
4.
Using wrench, loosen screw (5).
5.
Turn link connector assembly (6) until it comes off of tube (1).
6.
END OF TASK