TM 9-1220-220-34
2-2.
PERFORMANCE TEST (CONT)
NOTE
Performance test should be performed operating the system manually.
FRAME 1
Step
Procedure
Symptom
Maintenance Action
1.
Set COMPUTER SWITCH
...
...
(1) on range finder (2) to
OFF.
2.
Pull out and turn range
...
...
correction knob (3) on
ballistics computer (4) until
scale (5) reads 0 (zero).
3.
While looking into range
...
...
scale window (6) of range
finder (2), turn range
knob (7) until range scale
dial in window (6) reads
1000 meters.
4.
Check that inner (range)
...
...
pointer (8) of ballistics
computer (4) reads 1000
meters.
5.
Set driver's master control
...
...
panel (9) MASTER
SWITCH (10) to ON.
6.
Set COMPUTER switch (1)
...
...
on range finder (2) to ON.
GO TO FRAME 2