Table 4-2. Ice Maker Troubleshooting-Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
20. CUBES ON TOP OF BUCKET ARE FROSTY.
Step 1.
Check for poor gasket seal.
Replace seal.
Step 2.
Check if cubes have not been disturbed in a longtime.
Remove top layer of cubes.
21. BLACK BUTTONS ON WATER VALVE SWITCH, HOLDING SWITCH AND
SHUTOFF ARM SWITCH DO NOT CLICK WHEN DEPRESSED, AND THE
DOOR SWITCH HAS RUST AROUND THE WHITE PLUNGER.
The switches are defective.
Replace switch.
22. EJECTOR BLADES NEED ADJUSTING.
See No. 18 above.
23. DOOR SEAL IS INEFFECTIVE.
Check if the door hinge is sprung.
Put a screwdriver handle at the lower right-hand hinge between
the cabinet and the door and push gently on the top right-hand
corner. Repeat this on the left-hand side. This will spring the
door out at the bottom and push the top, where the poor seal is
located, in closer to the cabinet.
24. WATER KEEPS RUNNING AND WON'T SHUT OFF.
Step 1.
Faulty water valve switch.
Replace switch (para. 4-5c.).
Step 2,
Check for defective solenoid valve.
Replace valve if defective.
4-16
|