Click here to make tpub.com your Home Page

Page Title: UNIT NEEDS DEFROSTING WEEKLY.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6640-213-14
Table 4-2. Ice Maker Troubleshooting -Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. UNIT NEEDS DEFROSTING WEEKLY.
Step 1. Check if hot airis entering the front grille, causing unit to frost
up.
Assure that cool air supply is entering front grille.
Step 2.
Check for poor door seal, causing frost-forming warm air to
enter storage compartment or the door is not closed tightely.
Replace door seal if defective. Always ensure that the door
is properly closed.
Step 3.
Check if chemical content of the water has changed, causing the
water to freeze at a different temperature.
4. THE ICE MAKER IS FREEZING UP, STOPPING ICE CUBE PRODUCTION.
Slow current leakage through electric solenoid valve, causing continuous
freezing.
Replace solenoid valve.
5. ICE MAKER FAILS TO PRODUCE ICE.
Step 1.
Ejector blades are frozen in and cannot eject the cubes.
Defrost and restart the ice maker.
Step 2.
Faulty door switch causing malfunction of ice maker.
Replace door switch.
Step 3.
Low voltage or switch in unit compartment is in OFF position.
Check line voltage. Place switch in ON position.
4-10

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business